On-Board Diagnostics (OBD) Basics Diagnostic Service Definitions
4.4.5 Service $05:
Oxygen Sensor Monitoring Test Results
The purpose of this service is to allow access to the on-board oxygen sensor monitoring test
results (if implemented).
NOTE:
i Service $05 is not supported on CAN vehicles, and oxygen sensor test results are incorporated
into Service $06. Manufacturers are allowed to use Service $06 as an alternative to Service $05
for non-CAN vehicles.
Different manufacturers may use many methods to calculate test results for this service. The scan
tool converts test values and displays them in the standard units of measurement.
The ECM transmits the latest test results available from the system. Test results are retained by
the ECM, even over multiple ignition OFF cycles, until replaced by the results of a more recent
test. Test results are requested by Test ID. (See Test ID Table).
Test results can be reported either as a constant or as a calculated value, depending on the Test
ID. Calculated values are reported with minimum and maximum limits.
NOTE:
i Depending on the manufacturer, calculated values may be rounded off, which means that a test
may fail despite the values reading within min. and max limits.
The scan tool checks if the readiness status of oxygen sensors is completed. If the test is not
completed, the scan tool displays a warning.
Figure 4-4
Test ID Values Example
NOTE:
i Refer to Table 4-4 for an explanation of the individual Test ID numbers.
$06 $05
$07
$08
$0A $09
$04
$03
$02 $01
Rich
Lean
Oxygen Sensor Output
Numbers Refer to Test ID